 MIL-704 Training, MIL-STD-704 Training

MIL-STD-704 Training covers all aspects of MIL-STD-704 testing and measurement procedures in order to pass comprehensive testing to demonstrate compliance.

Learn how Electronic systems designed for operation in a U.S. DoD aircraft must comply with MIL-STD-704, which defines requirements and certain parameters and characteristics the electric power in an aircraft must meet:  pass comprehensive acceptance testing, measuring responses to a large set of events and conditions, including voltage transients, over- and under-frequency, over- and under-voltage and power transfer operations.

This 2-day MIL-STD-704 training covers the requirements and characteristics of aircraft electric power provided at the input terminals of electric and electronic equipment:  specific type of electrical power to be used and the detailed performance required during normal, abnormal, emergency, starting, transfer and power failure operation of the electric system in question.

FOR DETAILED AGENDA AND OUTLINE CLICK HERE

A cross reference to RTCA-DO-160 test methods is provided compared to MIL-STD-810F, MIL-STD-461 and MIL-STD-704.

Topics covered:

  • MIL STD 704  requirements and characteristics of aircraft electric power
  • Guidance: MIL-HDBK-704-1 through-8
  • Test methods and procedures for determining airborne utilization equipment compliance with the electric power characteristics requirements
  • Aircraft Electrical Power Characteristics with respect to standardized power interface between a military aircraft and connected or contained equipment and carriage stores, covering areas
  • Testing of voltage, frequency, phase, power factor, ripple, maximum current, electrical noise and abnormal conditions such as overvoltage and under voltage, for both AC and DC systems
  • Aircraft 28 V dc power interface
  • Aircraft 115/200 V 400 Hz ac power interface
  • Aircraft 270 V dc power interface

Learn how to perform the following MIL-STD-704 tests:

  • MIL-HDBK-704-1 – Demonstration of Utilization Equipment Compliance to Aircraft Electrical Power Characteristics
  • MIL-HDBK-704-2 – 115 Volt Single Phase, 400 Hz
  • MIL-HDBK-704-3 – 115 Volt Three Phase, 400 Hz
  • MIL-HDBK-704-4 – 115 Volt Single Phase, Variable Frequency
  • MIL-HDBK-704-5 – 115 Volt Three Phase, Variable Frequency
  • MIL-HDBK-704-6 – 115 Volt Single Phase, 60 Hz
  • MIL-HDBK-704-7 – 270 Volt DC
  • MIL-HDBK-704-8 – 28 Volt DC